{"product_id":"6-awg-13-mm-120a-ultra-flexible-tinned-copper-silicone-mppt-charger-battery-cable","title":"Ultra-Flexible Tinned Copper Silicone MPPT Charger Battery Cable","description":"\u003ch2 data-start=\"160\" data-end=\"251\"\u003ePrice is per 100mm. Please enter the quantity you require in units of 100 millimetres. Eg: 3 units = 300mm\u003c\/h2\u003e\n\u003ch4 data-start=\"160\" data-end=\"251\"\u003e6 AWG (13 mm²) 120A Ultra-Flexible Tinned Copper Silicone MPPT Charger Battery Cable\u003c\/h4\u003e\n\u003cp data-start=\"253\" data-end=\"625\"\u003eThe Greater Wire\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"257\" data-end=\"326\"\u003e6 AWG (13 mm²) Ultra-Flexible Inverter Battery Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for high-current (\u003cstrong data-start=\"493\" data-end=\"516\"\u003eContinuous current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"523\" data-end=\"531\"\u003e120A max)\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eDC power applications where reliability, flexibility, and longevity are essential. Built using\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"453\" data-end=\"488\"\u003eultra-fine strand tinned copper\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand premium\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"501\" data-end=\"541\"\u003ehigh-temperature silicone insulation\u003c\/strong\u003e, this cable is ideal for modern inverter, lithium battery, and solar power systems.\u003c\/p\u003e\n\u003cp data-start=\"627\" data-end=\"861\"\u003eDesigned to outperform standard PVC battery cable, Greater Wire silicone cable remains exceptionally flexible in tight spaces and extreme temperatures, making installation cleaner and more reliable in mobile and off-grid environments.\u003c\/p\u003e\n\u003ch3 data-start=\"868\" data-end=\"884\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"886\" data-end=\"1317\"\u003e\n\u003cli data-start=\"886\" data-end=\"960\"\u003e\n\u003cp data-start=\"888\" data-end=\"960\"\u003e\u003cstrong data-start=\"888\" data-end=\"916\"\u003e6 AWG (13 mm²) conductor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor efficient high-current power delivery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"961\" data-end=\"1051\"\u003e\n\u003cp data-start=\"963\" data-end=\"1051\"\u003e\u003cstrong data-start=\"963\" data-end=\"1007\"\u003eUltra-flexible fine-strand tinned copper\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy routing and vibration resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1052\" data-end=\"1120\"\u003e\n\u003cp data-start=\"1054\" data-end=\"1120\"\u003e\u003cstrong data-start=\"1054\" data-end=\"1094\"\u003eHigh-temperature silicone insulation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor superior durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1121\" data-end=\"1190\"\u003e\n\u003cp data-start=\"1123\" data-end=\"1190\"\u003eExcellent resistance to\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1147\" data-end=\"1188\"\u003eheat, oil, moisture, UV, and abrasion\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1191\" data-end=\"1246\"\u003e\n\u003cp data-start=\"1193\" data-end=\"1246\"\u003eReduced voltage drop for improved system efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1247\" data-end=\"1317\"\u003e\n\u003cp data-start=\"1249\" data-end=\"1317\"\u003eCorrosion-resistant construction, ideal for marine and coastal use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1324\" data-end=\"1346\"\u003eIdeal Applications\u003c\/h3\u003e\n\u003cul data-start=\"1348\" data-end=\"1549\"\u003e\n\u003cli data-start=\"1348\" data-end=\"1383\"\u003e\n\u003cp data-start=\"1350\" data-end=\"1383\"\u003eSolar controller to battery connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1419\"\u003e\n\u003cp data-start=\"1386\" data-end=\"1419\"\u003eLiFePO4 lithium battery systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1462\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1462\"\u003eSolar and off-grid power installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1463\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1503\"\u003eCampervans, caravans, and motorhomes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1504\" data-end=\"1549\"\u003e\n\u003cp data-start=\"1506\" data-end=\"1549\"\u003eMarine, automotive, and 4×4 power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1556\" data-end=\"1574\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-start=\"1576\" data-end=\"1897\"\u003e\n\u003cli data-start=\"1576\" data-end=\"1603\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1603\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1588\"\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGreater Wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1604\" data-end=\"1657\"\u003e\n\u003cp data-start=\"1606\" data-end=\"1657\"\u003e\u003cstrong data-start=\"1606\" data-end=\"1629\"\u003eConductor Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFine-strand tinned copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1692\"\u003e\n\u003cp data-start=\"1660\" data-end=\"1692\"\u003e\u003cstrong data-start=\"1660\" data-end=\"1675\"\u003eCable Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 AWG (13 mm²)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1692\"\u003e\n\u003cstrong data-start=\"493\" data-end=\"516\"\u003eContinuous current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"523\" data-end=\"531\"\u003e120A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1693\" data-end=\"1728\"\u003e\n\u003cp data-start=\"1695\" data-end=\"1728\"\u003e\u003cstrong data-start=\"1695\" data-end=\"1710\"\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSilicone rubber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1729\" data-end=\"1764\"\u003e\n\u003cp data-start=\"1731\" data-end=\"1764\"\u003e\u003cstrong data-start=\"1731\" data-end=\"1747\"\u003eFlexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUltra-flexible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1765\" data-end=\"1822\"\u003e\n\u003cp data-start=\"1767\" data-end=\"1822\"\u003e\u003cstrong data-start=\"1767\" data-end=\"1786\"\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for 12V \/ 24V DC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1823\" data-end=\"1897\"\u003e\n\u003cp data-start=\"1825\" data-end=\"1897\"\u003e\u003cstrong data-start=\"1825\" data-end=\"1852\"\u003eTemperature Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-temperature rated silicone insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1904\" data-end=\"1932\"\u003eWhy Choose Greater Wire?\u003c\/h3\u003e\n\u003cp data-start=\"1934\" data-end=\"2289\"\u003eGreater Wire cables are manufactured to meet the demands of modern power systems, delivering dependable performance in harsh environments. The combination of tinned copper conductors and silicone insulation ensures long service life, consistent conductivity, and easier installation—making it a trusted choice for professionals and serious DIY installers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGauge \/ Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 AWG \/ 35 mm² \/ 8.3mm total conductor diameter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-stranded tinned copper (≈ 6,700 × 0.08 mm strands)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-temperature, flexible silicone rubber\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOuter Insulation Diameter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 12.5 – 13 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 V (AC or DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 200 A per cable (can be doubled up for 400A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e−60 °C to +200 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~0.71 Ω\/km at 20 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColours:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack, Red\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"229\" data-end=\"267\"\u003eAmp Rating \u0026amp; Inverter Sizing Guide\u003c\/h3\u003e\n\u003cp data-start=\"269\" data-end=\"445\"\u003eThe Greater Wire\u003cstrong data-start=\"273\" data-end=\"342\"\u003e\u003cspan\u003e \u003c\/span\u003e6 AWG (13 mm²) Ultra-Flexible Silicone Battery Cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"359\" data-end=\"401\"\u003emedium-to-high current DC applications\u003c\/strong\u003e, including MPPT and inverter-to-battery connections.\u003c\/p\u003e\n\u003cp data-start=\"447\" data-end=\"490\"\u003e\u003cstrong data-start=\"447\" data-end=\"490\"\u003eTypical current ratings (conservative):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"491\" data-end=\"610\"\u003e\n\u003cli data-start=\"491\" data-end=\"531\"\u003e\n\u003cp data-start=\"493\" data-end=\"531\"\u003e\u003cstrong data-start=\"493\" data-end=\"516\"\u003eContinuous current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"523\" data-end=\"531\"\u003e120A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"532\" data-end=\"610\"\u003e\n\u003cp data-start=\"534\" data-end=\"610\"\u003e\u003cstrong data-start=\"534\" data-end=\"561\"\u003eShort-duration \/ surge:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"568\" data-end=\"580\"\u003e150–160A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g. inverter startup loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"612\" data-end=\"833\"\u003e\n\u003cp data-start=\"614\" data-end=\"833\"\u003eActual current capacity depends on cable length, installation method, ambient temperature, bundling, and ventilation. Always size cabling conservatively and protect with an appropriately rated fuse close to the battery.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2 data-start=\"877\" data-end=\"911\"\u003eRecommended Cable \u0026amp; Fuse Sizing\u003c\/h2\u003e\n\u003ch3 data-start=\"913\" data-end=\"969\"\u003eA) Battery Side (most important for 40A controllers)\u003c\/h3\u003e\n\u003cp data-start=\"970\" data-end=\"1016\"\u003eThis is where you size for\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"997\" data-end=\"1015\"\u003e40A continuous\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1018\" data-end=\"1057\"\u003e\u003cstrong data-start=\"1018\" data-end=\"1057\"\u003eCable sizing (controller → battery)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1058\" data-end=\"1319\"\u003e\n\u003cli data-start=\"1058\" data-end=\"1128\"\u003e\n\u003cp data-start=\"1060\" data-end=\"1128\"\u003eShort run (≤ 1.5 m one-way):\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1089\" data-end=\"1109\"\u003e8 AWG (8–10 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically ideal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1129\" data-end=\"1214\"\u003e\n\u003cp data-start=\"1131\" data-end=\"1214\"\u003eMedium run (1.5–3 m one-way):\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1161\" data-end=\"1179\"\u003e6 AWG (13 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erecommended to reduce voltage drop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1215\" data-end=\"1319\"\u003e\n\u003cp data-start=\"1217\" data-end=\"1319\"\u003eLong run (\u0026gt; 3 m one-way): consider\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1252\" data-end=\"1270\"\u003e4 AWG (21 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor relocate the controller closer to the battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1321\" data-end=\"1358\"\u003e\u003cstrong data-start=\"1321\" data-end=\"1358\"\u003eFuse \/ breaker (battery positive)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1359\" data-end=\"1474\"\u003e\n\u003cli data-start=\"1359\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1361\" data-end=\"1417\"\u003e\u003cstrong data-start=\"1361\" data-end=\"1381\"\u003e50A fuse\/breaker\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the common choice for a 40A MPPT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1474\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1474\"\u003ePlace it\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1429\" data-end=\"1453\"\u003eclose to the battery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(within ~150–200 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1476\" data-end=\"1612\"\u003eWhy 50A? You want the fuse to protect the cable and allow normal operation (40A continuous + small transients) without nuisance blowing.\u003c\/p\u003e\n\u003ch3 data-start=\"1619\" data-end=\"1663\"\u003eB) Solar \/ PV Side (panels → controller)\u003c\/h3\u003e\n\u003cp data-start=\"1664\" data-end=\"1711\"\u003eSize to your\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1677\" data-end=\"1701\"\u003epanel string current\u003c\/strong\u003e, not 40A.\u003c\/p\u003e\n\u003cp data-start=\"1713\" data-end=\"1731\"\u003e\u003cstrong data-start=\"1713\" data-end=\"1731\"\u003eFuse \/ breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1732\" data-end=\"1998\"\u003e\n\u003cli data-start=\"1732\" data-end=\"1877\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1877\"\u003eUse a PV-side fuse\/breaker sized to your array current (often\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1796\" data-end=\"1818\"\u003e15A–30A per string\u003c\/strong\u003e, depending on panels and how many strings are paralleled).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1878\" data-end=\"1998\"\u003e\n\u003cp data-start=\"1880\" data-end=\"1998\"\u003eIf you have\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1892\" data-end=\"1924\"\u003emultiple strings in parallel\u003c\/strong\u003e, string fusing is often required (common practice is fusing each string).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2000\" data-end=\"2016\"\u003e\u003cstrong data-start=\"2000\" data-end=\"2016\"\u003eCable sizing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2017\" data-end=\"2283\"\u003e\n\u003cli data-start=\"2017\" data-end=\"2181\"\u003e\n\u003cp data-start=\"2019\" data-end=\"2181\"\u003eFor many small-to-medium arrays feeding a 40A MPPT, PV current is often\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2091\" data-end=\"2101\"\u003e10–20A\u003c\/strong\u003e, so\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2106\" data-end=\"2124\"\u003e10 AWG (6 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2128\" data-end=\"2148\"\u003e8 AWG (8–10 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis common depending on distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2182\" data-end=\"2283\"\u003e\n\u003cp data-start=\"2184\" data-end=\"2283\"\u003eLonger PV runs benefit from thicker cable to reduce voltage drop (especially if PV voltage is low).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1619\" data-end=\"1663\"\u003eB) Recommended Inverter Sizing (12V Systems)\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"888\" data-end=\"1146\" height=\"524\" style=\"width: 27.1429%;\"\u003e\n\u003cthead data-start=\"888\" data-end=\"946\"\u003e\n\u003ctr data-start=\"888\" data-end=\"946\"\u003e\n\u003cth class=\"\" data-start=\"888\" data-end=\"904\" data-col-size=\"sm\" style=\"width: 26.5383%;\"\u003eInverter Size\u003c\/th\u003e\n\u003cth class=\"\" data-start=\"904\" data-end=\"925\" data-col-size=\"sm\" style=\"width: 27.0122%;\"\u003eApprox. DC Current\u003c\/th\u003e\n\u003cth class=\"\" data-start=\"925\" data-end=\"946\" data-col-size=\"sm\" style=\"width: 44.5465%;\"\u003eCable Suitability\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1004\" data-end=\"1146\"\u003e\n\u003ctr data-start=\"1004\" data-end=\"1029\"\u003e\n\u003ctd data-start=\"1004\" data-end=\"1011\" data-col-size=\"sm\" style=\"width: 26.5383%;\"\u003e600W\u003c\/td\u003e\n\u003ctd data-start=\"1011\" data-end=\"1018\" data-col-size=\"sm\" style=\"width: 27.0122%;\"\u003e~50A\u003c\/td\u003e\n\u003ctd data-start=\"1018\" data-end=\"1029\" data-col-size=\"sm\" style=\"width: 44.5465%;\"\u003e\n\u003cimg draggable=\"false\" role=\"img\" class=\"emoji\" alt=\"✅\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2705.svg\"\u003e\u003cspan\u003e \u003c\/span\u003eIdeal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1030\" data-end=\"1056\"\u003e\n\u003ctd data-start=\"1030\" data-end=\"1038\" data-col-size=\"sm\" style=\"width: 26.5383%;\"\u003e1000W\u003c\/td\u003e\n\u003ctd data-start=\"1038\" data-end=\"1045\" data-col-size=\"sm\" style=\"width: 27.0122%;\"\u003e~85A\u003c\/td\u003e\n\u003ctd data-start=\"1045\" data-end=\"1056\" data-col-size=\"sm\" style=\"width: 44.5465%;\"\u003e\n\u003cimg draggable=\"false\" role=\"img\" class=\"emoji\" alt=\"✅\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2705.svg\"\u003e\u003cspan\u003e \u003c\/span\u003eIdeal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1057\" data-end=\"1108\"\u003e\n\u003ctd data-start=\"1057\" data-end=\"1065\" data-col-size=\"sm\" style=\"width: 26.5383%;\"\u003e1500W\u003c\/td\u003e\n\u003ctd data-start=\"1065\" data-end=\"1073\" data-col-size=\"sm\" style=\"width: 27.0122%;\"\u003e~125A\u003c\/td\u003e\n\u003ctd data-start=\"1073\" data-end=\"1108\" data-col-size=\"sm\" style=\"width: 44.5465%;\"\u003e\n\u003cimg draggable=\"false\" role=\"img\" class=\"emoji\" alt=\"⚠️\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/26a0.svg\"\u003e\u003cspan\u003e \u003c\/span\u003eAcceptable (short runs only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1109\" data-end=\"1146\"\u003e\n\u003ctd data-start=\"1109\" data-end=\"1117\" data-col-size=\"sm\" style=\"width: 26.5383%;\"\u003e2000W\u003c\/td\u003e\n\u003ctd data-start=\"1117\" data-end=\"1125\" data-col-size=\"sm\" style=\"width: 27.0122%;\"\u003e~170A\u003c\/td\u003e\n\u003ctd data-start=\"1125\" data-end=\"1146\" data-col-size=\"sm\" style=\"width: 44.5465%;\"\u003e\n\u003cimg draggable=\"false\" role=\"img\" class=\"emoji\" alt=\"❌\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\"\u003e\u003cspan\u003e \u003c\/span\u003eNot recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cblockquote data-start=\"1148\" data-end=\"1288\"\u003e\n\u003cp data-start=\"1150\" data-end=\"1288\"\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1154\" data-end=\"1174\"\u003e1500W+ inverters\u003c\/strong\u003e, or cable runs longer than ~1.5 m, consider\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 AWG (35 mm²)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reduce voltage drop and heat buildup.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch4 data-start=\"1295\" data-end=\"1319\"\u003eFuse Recommendation\u003c\/h4\u003e\n\u003cul data-start=\"1320\" data-end=\"1457\"\u003e\n\u003cli data-start=\"1320\" data-end=\"1387\"\u003e\n\u003cp data-start=\"1322\" data-end=\"1387\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1336\"\u003eFuse size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125A–150A (depending on inverter and cable length)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1388\" data-end=\"1457\"\u003e\n\u003cp data-start=\"1390\" data-end=\"1457\"\u003eInstall fuse within\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1410\" data-end=\"1457\"\u003e150–200 mm of the battery positive terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1464\" data-end=\"1480\"\u003e24V Systems\u003c\/h4\u003e\n\u003cp data-start=\"1481\" data-end=\"1624\"\u003eAt\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1484\" data-end=\"1491\"\u003e24V\u003c\/strong\u003e, current is approximately\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1518\" data-end=\"1526\"\u003ehalf\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat of a 12V system, allowing higher inverter wattages to be supported with the same cable size.\u003c\/p\u003e","brand":"Oddies Marine","offers":[{"title":"Black","offer_id":52849960911164,"sku":null,"price":1.99,"currency_code":"NZD","in_stock":true},{"title":"Red","offer_id":52849960943932,"sku":null,"price":1.99,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0936\/6218\/3740\/files\/6awg-Photoroom_517b1ab9-4661-4dbb-932f-ff86ce006dad.webp?v=1773197417","url":"https:\/\/oddiesmarine.co.nz\/products\/6-awg-13-mm-120a-ultra-flexible-tinned-copper-silicone-mppt-charger-battery-cable","provider":"Oddies Marine","version":"1.0","type":"link"}